8
Setting up your Devireg
™
550 programmable
thermostat with your devimat
™
system
If the thermostat is displaying ‘CODE’, initially you will ONLY be presented with step 1 and
step 4, set these as described below.
Once you have either completed steps 1 and 4, or the controller is displaying something other than
‘CODE’, you must press and hold the button until
the word ‘CODE’ is displayed and follow the steps
below:
Step 1-Setup code
Step 2-Operating mode
Step 3-Temperature
readout
Step 4-Sensor selection
Step 5-Maximum fl oor
temperature selection
Step 6-Off periods
Step 7-Clock display
Step 8-Save settings
Rotate button to select code 0044 and then press
button once.
Rotate button to select ‘ALO’ and then press
button.
Rotate button to select °C and then press button.
Rotate button to select ‘FS’ to activate the fl oor
sensor, then press button (not rFs or rs).
At ‘nt’ rotate button to select either of the fol-
lowing temperature selection maximum fl oor
temperatures, then press button.
Tiles on timber based fl oors 29°C
Tiles on concrete based fl oors 40°C
Timber covered fl oors (parquet etc.) 27°C
‘LO’ should be displayed, you should rotate dial
to select -15°C, then press button.
Rotate button to select clock display as either 24
hours or 12 hours AM/PM.
Press button once.
Now you can set the time and day on the controller.
Step 9-Setting of clock
Press and hold button until is displayed in bottom
left corner. The display now shows the time and day
(number 1 represents Monday, number 7 is Sunday).
Rotate the dial to show the correct time and day of the
week and then press the button to save the correct time
setting.
*If any steps are skipped, hold button until word ‘CODE’ is displayed to reset controller and start
again at step 1.
0044
FS
29ºC
LO -15ºC
24 12
(If the controller is now displaying ‘CODE’, disconnect the power to the controller and then recon-
nect)