Installation complete
Following installation the Warranty
Certifi cate on the back of this user
guide should be fi lled in.
The Devimat
system should not be
turned on until the adhesive and tile
grout has completely dried, then once
dried it can be turned on gradually
over a 48 hour period.
No close fi tting objects should be laid
or fi xed to the warm fl oor area, for
example thick mats or beanbags.
Testing
At each stage of the installation it is recommended that the heating mat is tested
for the following:
Continuity- This checks that the heating cable (blue and black wires) are intact
and have the correct resistance. The resistance is checked with a multimeter
and the reading should match the resistance rating on the label on the cold tail of
the Devimat
with a tolerance of -5 to +10%. Ensure your multimeter is capable
of reading values between 28-550 ohms.
Insulation- This checks that the earth screen around the heating cable has not
been damaged and shorted to the heating cables. The test can be made with a
multimeter and can be done by testing the path between the blue cable and the
earth screen and the black cable and the earth screen, both should read infi nity.