INT
9
Trouble shooting
Clock symbol flashing:
Time settings were lost due to power cut.
The thermostat resumes to manual mode.
E4 flashing in display:
Error code 4 – The thermostat has overheated
and has switched off
Let the thermostat cool for period. Then switch
the thermostat off and on.
E5 or E6 flashing in display:
Error code 5 - Floor sensor short circuited.
Error code 6 - Floor sensor disconnected.
Check connections, if they are OK, then discon-
nect the 2 sensor wires and connect an ohm
meter to sensor wires.
Measure the ohm value and check with the
values in the table in Technical Specifications
below.
Light Indications (LED)
The Devireg
TM
535 has a LED above the 2 pole safety switch.
The LED has five indications:
No light The system is turned off.
Green light System is standing by, set point
temperature reached
Green light flashing Floor sensor is defect
Red light System is heating
Switching between
red and green light
The floor temperature limit pre-
vents the set point room tempera-
ture from being reached.